Salt spray testing is an accepted method for assessing the suitability of stainless steel parts and fabrications that are likely to encounter chloride environments in service.

For any particular part, tested under laboratory conditions, a difference in performance between say, 430 (1.4016), 304(1.4301) and 316 (1.4401) types stainless steel would be expected, but the test outcome is sensitive to the shape of the parts (designed-in crevices), surface finish and the test conditions. Using specific laboratory salt spray test data to assess if a particular stainless steel grade is suitable for a specific or 'generic' environment is therefore not appropriate.

Salt spray test methods

Salt spray testing is covered by the standards such as:
ASTM B 117 - Practice for Operating Salt Spray (Fog) Testing Apparatus Tests durations may be up to 260 hours.
BS7479:1991 - Method for Salt Spray Corrosion Tests in Artificial Atmospheres. 
This supercedes BS5466:1977 and is equivalent to ISO 9227.
The test duration's range from 2 to 96 hours. The pass / fail criteria is that thers should not be any 'visible' staining on parts tested. The test acceptance criteria can therefore be subjective and need to be clearly defined for any set situation.

This standard covers methods in three types of atmospheres:

    Neutral
    Acetic acid
    Copper accelerated acetic acid (CASS)
Comparison of 316, 430 and 304 type stainless steel in salt spray testing

Results from one testing laboratory, based on tests done to the ASTM B117 method suggest a 316 type stainless steel part could be expected to pass a 96 hour test using a 3% salt spray.
Indications are that longer test times would not be expected to give satisfactory results.

In contrast, 304 type stainless steel parts would not be expected to give satisfactory results in a 3% salt spray, but if the salt solution concentration is reduced to 0.3 %, then it is possible that a 304 type stainless steel parts may be satisfactory for test times up to 120 hours.
This could also apply to 430 type ferritic or 431 type martensitic stainless steel parts.

Source: Yaang Pipe Industry Co., Limited (www.yaang.com)

Tel No:+86-18267732328 / Email:[email protected]
Address:Longwan District, Wenzhou, Zhejiang Province, China.

Copyright Notice © www.yaang.com Yaang Pipe Industry Co., Limited All rights reserved.
Yaang Pipe Industry Co., Ltd. is an international supplier of piping solutions for flange, butt welding fittings, socket welding fittings and threaded fittings. Our products are widely used in different industrial fields, including oil and gas, chemical industry, petrochemical industry, power plant, pulp and paper industry, environmental and water conservancy engineering, engineering projects, etc.